Researchers find up to 2.28% annual wave-induced losses in floating PV systems

pv magazine Global logo

Published on

Add as a preferred source on Google
Researchers find up to 2.28% annual wave-induced losses in floating PV systems

A research team in Norway has expanded a model for wave-induced loss (WIL) in floating photovoltaics (FPV) that it first presented in 2025. The updated framework uses site-specific, time-correlated wave and solar irradiance data to estimate annual energy losses under realistic weather conditions, including cloudy periods.

“While the previous study enabled an understanding of the WIL effect from variations in individual parameters, this work simulates WIL throughout the year, taking into consideration the varying environmental conditions,” the researchers said. “The expanded modeling framework is used to simulate WIL, wave-induced irradiance variation (WIIV), and wave-induced mismatch loss (WIML) for the year 2023 at four nearshore locations along the Norwegian coast.”

The framework consists of four modeling steps. First, in a step added to the original model, the researchers used the SWAN wave model to generate hourly, site-specific sea-state parameters based on wind, boundary wave spectra, and bathymetric data. Second, they used their existing 3DFloat approach to simulate panel movements, assuming that each panel directly follows local wave motion. This step now accounts for changing sea states throughout the year and allows for a more flexible wave spectrum.

In the third step, the researchers used pvlib to calculate the irradiance reaching each moving panel and an equivalent stationary reference panel, accounting for panel orientation and reflection losses. Unlike the previous study, which relied on clear-sky calculations, the updated model uses time-correlated irradiance data that include cloudy periods. Finally, the researchers used the existing PVMismatch electrical model to calculate individual panel and string output, which they integrated over time to determine energy production.


Source link

Disclaimer

We strive to uphold the highest ethical standards in all of our reporting and coverage. We TheMorningPulse.fyi want to be transparent with our readers about any potential conflicts of interest that may arise in our work. It's possible that some of the investors we feature may have connections to other businesses, including competitors or companies we write about. However, we want to assure our readers that this will not have any impact on the integrity or impartiality of our reporting. We are committed to delivering accurate, unbiased news and information to our audience, and we will continue to uphold our ethics and principles in all of our work. Thank you for your trust and support.