CONNECT WITH US
EV & Mobility

EV & Mobility

comemso’s Easy Chester Micro tests AC chargers and their ISO 15118-2 communication

Charged EVs logo

Published on

Add as a preferred source on Google
comemso’s Easy Chester Micro tests AC chargers and their ISO 15118-2 communication

German test-equipment maker comemso has launched the Easy Chester Micro, a portable tester that combines charging and communication tests with optional safety tests for AC wall boxes and charging stations.

The device includes an installation tester and an adapter box in one 5.4 kg case, rated IP 66 when closed. Electricians and service teams use it during commissioning, maintenance, periodic inspection and after repairs. A 10.1-inch touchscreen guides them through every step; no laptop or customer vehicle is needed.

The tester simulates the vehicle to IEC 61851-1 and SAE J1772. It measures the Control Pilot (CP) voltage, PWM duty cycle and Proximity Pilot (PP) values through a Type 1 or Type 2 AC inlet, depending on configuration. If a station supports ISO 15118-2, the tester sets up that communication without an external protocol converter. Charging is authorized via External Identification Means (EIM) such as an RFID card or app.

Since January 8, 2026, the EU’s Alternative Fuels Infrastructure Regulation (AFIR) has required new or renovated public charging points to comply with EN ISO 15118-1 to -5. An ISO 15118-2 test with the Easy Chester Micro also checks the station’s powerline communication (PLC) chip and PLC link to the vehicle. The test report records the Signal Level Attenuation Characterization (SLAC) connection setup, its attenuation value and the station’s PLC MAC address.

The tester does not replace a full AFIR conformity assessment. Support for ISO 15118-20 is planned for the first quarter of 2027. TLS-secured charging sessions are not supported. For DC stations, comemso offers the Easy Chester Ultimate .


Source link

Disclaimer

We strive to uphold the highest ethical standards in all of our reporting and coverage. We TheMorningPulse.fyi want to be transparent with our readers about any potential conflicts of interest that may arise in our work. It's possible that some of the investors we feature may have connections to other businesses, including competitors or companies we write about. However, we want to assure our readers that this will not have any impact on the integrity or impartiality of our reporting. We are committed to delivering accurate, unbiased news and information to our audience, and we will continue to uphold our ethics and principles in all of our work. Thank you for your trust and support.